Customization: | Available |
---|---|
Power Supply: | 220V 50/60Hz |
Certification: | CE, TUV, ISO, SGS |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | YUV-080 | |
Test area size W×H×D(cm) | 40×50×40 | |
Exterior chamber size W×H×D(cm) | Depends on the chamber design | |
performance | Temp.range | RT+10ºC~70ºC |
Humi.range | 75%RH~95%RH | |
Rain time | 1~99999mins,adjustable | |
Rain period | 1~240mins,interval adjustable | |
Light model | UV-A(295~360nm),UV-B(280~315nm)optional | |
UVA/UVB light power | 40W(lifetime 1800h) | |
Irradiance | 1.0W/m2 adjustable | |
Standard specimen size | 75×150mm or 75×300mm | |
Control accuracy | ±0.1ºC,±1%RH | |
System | Temp.controller | Imported LED digital display PID+SSR microcomputer integrator |
Sensor | Perkin resistance PT100Ω/MV | |
Time controller | Imported programmable time controller | |
Heating system | Nichrome heater | |
Condensation humidification system | Stainless steel humidifier | |
Blackboard temp | Metal blackboard thermometer | |
Water supply system | Auto water filling system | |
Circulating system | Quiet motor,multi-vane centrifugal fan | |
Material | Exterior chamber material | Stainless steel |
Inner chamber material | SUS#304 stainless steel | |
Sample holder material | SUS#304 stainless steel | |
Standard configuration | Standard sample holder 24pcs,light tubes 8pcs(UVA/UVB) | |
Safety Protection | Leakage,short circuit,over temp.,water shortage,over current protection | |
Power supply | AC 1ψ220V 60/50Hz | |
Operation condition | 5ºC~+30ºC≤85%RH | |
Customization service | Non-standard or special requirements are all welcome |