Medicine Industrial Temperature Vacuum Stable Drying Oven
Introduction
Medicine Industrial Temperature Vacuum Stable Drying Oven can provide a stable testing space and temperature for pre-heating, drying, changes about physics and chemistry testing. It adopts high precision temperature controller with high
Stability of platinum resistance to temperature that makes temperature well distribution. It is widely used to test a variety of products, materials, electric, instruments, meters, components, electronics, electricians
And automobiles, aviations, plastics, machinery, chemicals, foods, hardware tools for doing drying test
And various constant adaptive tests at an constant temperature condition.
Performance Feature
1. Adopt computerized electronic digital control, precise & reliable.
2. The packing of box insulation is molded by silicone, high-temperature enduring & never aged
Attached with observation view window, easy to be used.
3. Heating is by compulsory circulating ventilation, temperature raising is fast and spread even.
4. Provide the P. I. D. Control system, double sided overheating protection, safe & reliable.
5. Easy to set temperature, easier to operate.
6. Attached with two sets of movable disks to be adjusted high and low at your dispel.
What is reliability testing?
In order to evaluate and analyze the reliability of electronic products, the test is called reliability test. For different products, in order to achieve different purposes, you can choose different reliability test methods. Reliability test: also called product reliability evaluation, the product's ability to complete the specified functions under specified conditions and within a specified time. In the process of design and application, the product is constantly subjected to the influence of itself and the external climate environment and mechanical environment, but still needs to be able to work normally, which needs to be verified with test equipment. This verification is basically divided into R&D test and trial production test. , Three parts of mass production sampling. Reliability tests include: aging test, temperature and humidity test, gas corrosion test, mechanical vibration test, mechanical shock test, collision test and drop test, dustproof and waterproof test, packaging pressure test and other environmental reliability tests.
Reliability test:
1. Temperature lower limit work test: the tested sample is powered on and run the test program for initial test. Under the condition that the tested sample is not working, the temperature in the chamber is gradually reduced to 0ºC. After the temperature is stable, power on and run the test program for 5 hours. The function and operation of the tested sample should be normal. After the test, wait for the chamber temperature Return to room temperature, take out the sample, and recover for 2 hours under normal atmospheric pressure.
Recommended inspection standard: the function and operation of the tested sample should be normal, and there should be no obvious deviation in appearance.
2. Low-temperature storage test Put the sample in a low-temperature chamber, lower the chamber temperature to -20°C, store the sample for 16 hours without working, take the sample back to room temperature, restore it for another 2 hours, and run the test program after power on In the final inspection, the function and operation of the tested sample should be normal, and there should be no obvious deviation in appearance. In order to prevent the test sample from frosting and condensation during the test, the test sample is allowed to be sealed with a polyethylene film and then tested. If necessary, a moisture absorbent can be installed in the sealing sleeve.
Recommended inspection standard: the function and operation of the tested sample should be normal, and there should be no obvious deviation in appearance.
3. Working test of upper temperature limit The test sample shall be tested for the first time. Under the condition that the tested sample is not working, gradually increase the temperature of the box to 40ºC. After the temperature is stable, power on and run the system diagnostic program for 5 hours. The function and operation of the tested sample should be normal. After the test, wait for the chamber temperature Return to room temperature, take out the sample, and recover for 2 hours under normal atmospheric pressure.
Recommended inspection standard: the function and operation of the tested sample should be normal, and there should be no obvious deviation in appearance.
4. High-temperature storage test Put the sample into a high-temperature box, raise the temperature of the chamber to 55°C, store the sample for 16 hours without working, take the sample back to room temperature, and recover for 2 hours.
Recommended inspection standard: the function and operation of the tested sample should be normal, and there should be no obvious deviation in appearance
Technicial parameters
Model No. |
YVO-072 |
YVO-270 |
YVO-480 |
YVO-600 |
YVO-720 |
YVO-1000 |
Internal chamber size (W*H*D) cm |
40×45×40 |
60×90×50 |
80×100×60 |
100×100×60 |
100×120×60 |
100×100×100 |
External chamber size (W*H*D) cm |
72×116×56 |
93×163×67 |
110×172×77 |
130×172×77 |
116×170×116 |
116×150×166 |
Temperature range |
RT+25ºC~200ºC(Max. 400ºC) |
Vacuum degree |
Normal pressure to 3K Pa (Min 5 Pa can be customized) |
Temp fluctuation |
±3%ºC |
Control resolution |
0.1ºC |
Heat-up time |
RT+25~200ºC<90min |
RT+25~400ºC<120min |
External chamber material |
Cold rolled sheet + powder coating |
Interior chamber material |
SUS#304 Stainless steel |
Insulation |
fiberglass wool |
Heating system |
SUS#Stainless steel high-speed heater |
Control system |
Button type digital display controller |
Vacuum system |
Vacuum pump + solenoid valve + vacuum gauge |
Power supply |
AC 3Ψ 380V 60/50Hz |
Customazition service |
Non-standard or special requirements can be customized. |
Except Medicine Industrial Temperature Vacuum Stable Drying Oven, we also can supply:
Precision Oven Tester, Triple Type Temp. & Humi. Chamber, Temp. &Humi. Control Host, Air Thermal Shock Tester, Liquid Thermal Shock Tester, Salt Spray Tester, Walk-in environmental Test Room, Temp. Humi. &Vibration Conbined Test Chamber, Aging Oven Tester, Rain/Spray Test Chamber, Burn-in test equipment, Dust Tester, Steam Aging Tester, Vibration Tester, Tensile Tester, Drop Tester and so on.
If you have any question, please feel free to contact us!
Company profile